2x One-Step RT-PCR Master Mix - Convenient ready-to-use solution
- High sensitivity and yield
- Robust amplification
- Available in 3 convenient sizes: 100, 200 and 500 reactions (20 µL vol)
- Convenient - With the ready-to-use Master Mix, the user needs only to add template, the primer set and water to the master mix in order to set up the RT-PCR reaction.
- Time Savings - Set up RT-PCR reactions in a shorter time, as less pipetting steps are required.
- Cost Efficient - No need to buy separate enzymes, dNTPs and buffers. All are included with the ready-to-use Master Mix.
- High Sensitivity and yield – the optimized Master Mix allows for highly sensitive amplifications with high yields of PCR products.
- Robust Amplification - BSI’s 2X One-Step RT-PCR Master Mix is capable of amplifying difficult templates with a high degree of reproducibility.
Figure 1. Successful Amplification of Different Sized Amplicons. BSI’s 2X One-Step RT-PCR Master Mix was used in RT-PCR reactions to amplify a number of different amplicons. Lanes 1 and 2 correspond to the E. coli 16s rRNA gene (large amplicon), which is 1.5 kb in size. Lanes 3 and 4 correspond to the E. coli 16s rRNA gene (small amplicon), which is 550 bp in size. Lanes 5 and 6 correspond to the human S15 gene, which is 360 bp in size. Lanes 7 and 8 correspond to the human 5S rRNA gene, which is 120 bp in size. BSI’s 2X One-Step RT-PCR Master Mix was able to amplify all the different sized products with a high sensitivity and yield. SPECIFICATIONS
Figure 2. Robust Amplification from Different Amounts of RNA Input. BSI’s 2X One Step RT-PCR Master Mix was used to amplify the human S15 transcripts from a dilution series of HeLa total RNA isolated using BSI’s Total RNA Purification Kit. The 361 bp amplicon was robustly amplified from a broad range of RNA inputs, from the ng range down to fg range. Reagents supplied – Cat # NB-28113 2X One-Step RT-PCR Master Mix (1 Vials, 100 Reactions) - Sufficient reagent for 100 x 20 µL reactions Reagents supplied – Cat # NB-28114 2X One-Step RT-PCR Master Mix (2 Vials, 100 Reactions each) - Sufficient reagent for 200 x 20 µL reactions Reagents supplied – Cat # NB-28115 2X One-Step RT-PCR Master Mix (5 Vials, 100 Reactions each) - Sufficient reagent for 500 x 20 µL reactions Storage Conditions and Product Stability 2X One-Step RT-PCR Master Mix should be stored at -20°C. For everyday use an aliquot can be stored at 4°C for up to 3 months. Repeated freeze-thaw cycles are not recommended. When stored at the proper temperature this reagent is stable for at least 1 year. Long-Term Storage : X One-Step RT-PCR Master Mix should be stored at -20°C. For everyday use an aliquot can be stored at 4°C for up to 3 months. Repeated freeze-thaw cycles are not recommended. When stored at the proper temperature this reagent is stable for at least 1 year. Product Usage For laboratory research use only, not for diagnostic use! Not for use in humans.For more detail regarding Peptides please visit here : Custom Peptide Synthesis
No comments:
Post a Comment